4 Device description

The Weller WX 2 is a versatile repair station for professional repair
work on state-of-the-art electronic modules in industrial
manufacturing, repair workshops and laboratories.
The digital control electronics in combination with superior sensor
and heat-transfer technology guarantee precise temperature control
at the soldering tip. High-speed measured-value acquisition gives
maximum temperature precision and optimal temperature response
under load.
The temperature can be adjusted within a range of 0 °C – 550 °C
(150 °F – 999 °F) for soldering tools and microtools. Specified and
actual values are displayed digitally. There are four buttons (2 per
tool) for saving fixed temperature presets.
The Weller WX 2 Soldering Station has the following functions and
features:
− Modern operating concept and navigation
− Controlled using sensor buttons
− Multilingual menu navigation
− LC graphic display with blue LED backlighting
− Suitable for all tools up to 200 W or simultaneous
use of 2 x 120 W soldering irons
− No calibration needed
− Two connections for soldering tools with integrated parameter
memory (e.g. for fixed temperature)
− Automatic tool detection and activation of soldering-iron-specific
control parameters
− Digital temperature control
− Antistatic device design in accordance with ESD safety
− Different equipotential-bonding possibilities on the device
(standard configuration: hard grounded)
− Settings for soldering-iron-specific parameters such as: standby
temperature; standby time ; AUTO OFF time; offset; control
response; process window; robot output
− Settings for station-specific parameters such as: language;
temperature version °C/°F; password; touchtones on/off; LCD
contrast; LCD background brightness; screen saver
− Two connections for peripheral devices (e.g. WFE, WHP)
− Digital and optically decoupled robot connection
− USB port for memory stick (for firmware updates, configuration
and monitoring)
5-20