13. Troubleshooting

Problem
No water supply to the device
Device does not regenerate
Nothing is displayed
Incorrect time is displayed
Insufficient function
*CS = Customer services tel. 0 18 01 - 46 63 88

14. Spare Parts

No. Description
1
Disinfection unit
2
Disinfection unit
for devices produced from August
2013 onwards
3
Controller head seal kit
4
Spare part kit for brine pump
5
O-ring set
6
Turbine water counter
7
Bypass/blending valve for KS10S
8
Stainless steel corrugated pipe for
KS10S
9
Transformer KS10S
10 Control panel for KS10S

15. Accessories

D06F
Pressure reducing valve
Honeywell GmbH
GB
Cause
Shut-off device in the bypass is not open or
only partially open
Pipework of the drinking water supply is
calcified or blocked
Flow meter is defective
Internal electric cabling is defective
Wrong connection of connecting hoses
Rotary disc valve defective
Power supply has been interrupted
Rotary disc valve defective
Power failure occurred
Device not deaerated
Storage tank is almost or completely empty Check salt level
Blending has been set incorrectly
Control valve is contaminated or defective Call Technical Customer Service
Part No.
DE10S-A
DE10S-AN
F76S
EK10S-A
EK10S-B
OFV10S-A Bypass valve insert
EK10S-C
EK10S-D
BV10S-A
CP10S-A
TR10S-A
CE10S-A
13
Remedy
Open shut off valve fully
Clean or replace the pipework
Check and, if necessary, replace the flow
meter (CS*)
Check internal electric cabling (CS*)
Connect the flexible connection lines
correctly
Call Technical Customer Service
Check power suppy (mains plug, fuse)
Call Technical Customer Service
Set the time
Deaerate device
Check blending valve and mixing ratio
Noise protected pressure reducing valve with
setting scale. Maximum inlet pressure 16 bar,
with brass filter bowl 25 bar, outlet pressure
range 1.5 - 6.0 bar
A = With clear filter bowl up to 40 °C / 16 bar
B = With brass filter bowl up to 70 °C / 25 bar
Fine filter, reverse rinsable
AA= With clear filter bowl
AAM= With red bronze filter bowl
if a pressure scourer is applicated it is necces-
sary to fit a bypass valve insert into the bypass
valve.