9.1.2. Basic settings for commissioning - time, raw water
hardness, regeneration time and cleaning function
There is a connection to the power supply
Display Current time flashes
AKTUELLE ZEIT
1. Set the time by pressing + or -
2. Confirm with MENU / OK
Display Hardness flashes
HÄRTE
1. Set the raw water hardness by pressing + or -
The hardness of the raw water can be inquired from the
water distribution company.
2. Confirm with MENU / OK
• Display Regeneration time flashes
REGENERATION
ZEIT
Factory setting for start time for regeneration: 2:00 AM
Start time can be modified by pressing + and -
1. Confirm with MENU / OK
Anzeige Clean (Reinigungsfunktion) blinkt (bei KS10S-30)
Factory setting is Clean: On
Factory setting can be modified by pressing + and -
Modifying the factory setting is not recommended
Factory setting for rinsing duration: 4 minutes
1. Confirm with MENU / OK
Honeywell GmbH
GB
9.1.3. Setting the mix water hardness
It is recommended to set a residual water hardness of at
least 8°dH to avoid corrosion damages.
It is recommended to check the output water hardness
regularly (2 times a year).
1. Setting the mix water hardness by turning the screw at the
base of the diluting device
• Use screwdriver
• Turn counter-clockwise = increase water hardness on
output side
• Turn clockwise = decrease water hardness on output
side
2. Check the mix water hardness at a tapping point
• Open tapping point completely to ensure sufficient flow
3. Readjust by turning the screw if necessary
• Hex allen wrench needed - M4mm
9.1.4. First Regeneration
1. Start regeneration
• Press the Regeneration key for 5 seconds
• Display Regeneration active flashes
• The time is displayed in the display during the regene-
ration process
REGENERATION AKTIV
2. After the end of the regeneration
• Display Regeneration active goes out.
• The time is displayed
3. The device is ready for operation
11