Warning codes
fig. o B, page 16.
E.g. see
Warning code
Fault
!WARNING 32
Fan over-current
!WARNING 33
Compressor start
fail
!WARNING 34
Compressor
speed low
!WARNING 35
Controller over-
temperature
!WARNING 01
NTC open circuit
SZ & DZ LARGE
!WARNING 11
NTC open circuit
DZ SMALL
!WARNING 02
NTC short circuit
SZ & DZ LARGE
!WARNING 12
NTC short circuit
DZ SMALL
!WARNING 09
DZ valve or Ice
Maker valve faulty
!WARNING
Communication
03/43
error
EN
Possible cause
Internal fault.
High ambient
temperature
Air vent blocked
or insufficient
clearance
Internal fault
Internal fault
Troubleshooting
Suggested remedy
Turn off the device for at
least 5 mins., then restart. If
the problem persists,
authorised repair centre
inspection required
Turn off the device for at
least 30 mins., or move
to a cooler location,
then restart
Clear the vents
Authorised repair centre
inspection required
Authorised repair centre
inspection required
Turn off the device for at
least 1 min., then restart. If
the problem persists,
authorised repair centre
inspection required