N o s e A s s e m b l i e s
F i t t i n g I n s t r u c t i o n s
The air supply must be disconnected when fitting or removing nose assemblies.
Item numbers in bold refer to nose assembly components in all 3 nose tip tables.
•
Lightly coat jaws 4 with Moly lithium grease*.
•
Drop jaws 4 into jaw housing 3.
•
Insert jaw spreader 5 into jaw housing 3.
•
Locate buffer 6 on jaw spreader 5.
•
Locate spring 7 onto jaw spreader 5.
•
Fit locking ring 8 onto the jaw spreader housing of the tool.
•
Holding tool pointing down, screw the assembled jaw housing onto the jaw spreader housing and tighten with spanner.
•
Screw the nose tip into nose casing 1 and tighten with spanner*.
•
Place nose casing 1 over jaw housing 3 and screw onto the tool, tightening with spanner*
S e r v i c i n g I n s t r u c t i o n s
Nose assemblies should be serviced at weekly intervals. You should hold some stock of all internal components of the nose assembly
and nose tips as they will need regular replacement.
•
Remove the nose equipment using the reverse procedure to the 'Fitting Instructions'.
•
Any worn or damaged part should be replaced.
•
Clean and check wear on jaws.
•
Ensure that the jaw spreader is not distorted.
•
Check spring 7 is not distorted.
•
Assemble according to fitting instructions above.
Item numbers in bold refer to the illustrations on pages 8 and 10.
* Item included in the G2-s service kit. For complete list see page 18.