P r i m i n g
P r i m i n g P ro c e d u r e
All operations should be carried out on a clean bench, with clean hands in a clean area.
Care MUST be taken at all times, to ensure that no foreign matter enters the tool, or serious damage may result.
•
Remove bleed screw 10 and seal 11.
•
Connect air supply to the intensifier.
•
Screw the non-return valve assembly (part number 07900-00714 from the Service Kit) into the hole for bleed screw 10.
•
Place the end of the rubber tube of the non-return valve assembly over a suitable oil collecting container.
•
Fill the reservoir of the intensifier with Hyspin oil.
•
Fully actuate the trigger and hold for 2 seconds before releasing. Oil will be drawn into the system from the reservoir.
•
Repeat this last step until the oil expelled out of the non-return valve is totally clear of air.
•
Keep placing head below oil level of Intensifier.
•
Remove the non-return valve assembly.
•
Replace bleed screw 10 and seal 11 and top up the oil in the reservoir of the intensifier.
•
Check that the stroke of the tool meets the minimum specification of 17 millimetres. To check the stroke, measure the distance between
the front face of jaw spreader housing 1 and the front face of the head, BEFORE pressing the trigger and when the trigger is fully
actuated. The stroke is the difference between the two measurements. If it does not meet the minimum specification, repeat the priming
procedure.
Item numbers in bold refer to the general assembly drawings and parts lists pages 22-25.
I M P O R T A N T
Ensure that the new oil is perfectly clean and free from air bubbles.
E n g l i s h
27