Cebora 452 Manual De Instrucciones página 8

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

BB. LED Hold.
This lights up automatically at the end of the welding
process to indicate that displays AR and AS show the
two most recent current and voltage measured values.
BD. JOB key.
Pressing this key calls up a stored welding point. The
AW knob is used to select the previously stored JOB
number.
BC. LED JOB.
This lights up when the BD key is selected.
BE. LED Remote control.
This lights up when any remote command is connected
to the connector E.
BG. LED Cooling unit.
It lights up when the cooling unit is on.
BF. Wire return key.
When this key is pressed, the motor rewinds the
welding wire by a few centimetres.
This operation takes place with no voltage present in
the torch and no gas flow.
BH. Wire test key.
When this key is pressed, the wire is fed up to 8 m/min
with no voltage present in the torch and no gas flow.
BL. Gas test key.
When this key is pressed, the gas flows out for 30
seconds. If pressed again during gas flow, the flow
stops.
BI. LED Quality control.
It lights up when the Quality Control accessory is
active and connected to the machine.
8
Tabla de contenido
loading

Tabla de contenido