13. CONTROLLED ENTRY AND AUTOMATIC EXIT

This solution is recommended when you want to enter a reserved area in both directions. To enter, transit is allowed by means of a reco-
gnition command while exiting is automatic.
ENTRY
S2
S2
EXIT
S2
S2
Loop S1 also perform as safety function not permitting the barrier closure as long as barrier is occupied.
DIMENSIONS
S2
- Connect the coil S1 to the CLOSE input.
- Connect the N.O. contact of the S2 loop receiver to input START.
- The dimensional values of the loops are only approximate.
*
We suggest installing the "RME 2" metal mass detector.
- Only use recognition systems other than remote control units (badge readers, video camera systems with license plate
recognition etc.) with contact, which must be connected to the OPEN input.
PARAMETER
DATA






Control unit
S1
S1
S1
S1
S1
4000
DESCRIPTION
Automatic
The close control closes when pressed and released, and also functions as a safety system.
Advanced Setup: controlled entry and automatic exit
2000
1600
- 32 -
The recognition system enables bar-
rier opening.
If the coil S1 is not occupied within the
pause time, the barrier closes again.
When coil S1 is cleared, the barrier
starts closing instantaneously.
The vehicle approaches the reserved
area. When the coil S2 is occupied,
barrier opening is enabled.
If the coil S1 is not occupied within the
pause time, the barrier closes again.
When coil S1 is left, the barrier starts
closing instantaneously.
1000
2000