Porta-Nails 465SLT Manual De Instrucciones página 12

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

AIR SUPPLY
1. Power Source
Use only clean, dry, regulated compressed air as a power source for this Tool
Air compressors used to supply compressed air to this Tool must comply with the requirements of the
latest version of ANSI Standard B 19 .3 "Safety Standard For Compressors For Process Industries ."
Moisture or oil in the air compressor may accelerate wear and corrosion in the Tool . Drain daily .
Air volume is as important as air pressure . The air volume supplied to the tool may be inadequate
because of undersized fittings and hoses or from the effects of dirt and water in the system . Restricted
air flow will prevent the tool from receiving an adequate volume of air, even though the pressure reading
is high . The results will be slow operation, jamming, miss-feeds or reduced driving power . Before
evaluating tool problems for these symptoms, trace the air supply from the tool to the supply source for
restrictive connectors, swivel fittings, low points containing water and anything else that would prevent
full volume flow of air to the tool .
2. Filter-Regulator-Lubricator
A pressure regulator with an operating pressure of 0-125 psi (0-8 .6 bar 0-8 .8 kgf/cm
control the operating pressure for safe operation of this Tool . Do not connect this Tool to air pressure
which can potentially exceed 200 psi as Tool may fracture or burst, possibly causing injury .
Filter-Regulator-Lubricator units supply an optimum condition for the Tool and extend the Tool life .
These units should always be used
Filter- The filter removes moisture and dirt mixed in compressed air . Drain daily unless fitted with an
automatic drain . Keep the filter clean by regular maintenance .
Regulator- The regulator controls the operating pressure for safe operation of the Tool . Inspect the
regulator before operation to be sure it operates properly .
Lubricator- The lubricator supplies an oil mist to the Tool . Inspect the lubricator before operation to be
sure the supply of lubricant is adequate . Use Porta-Nails pneumatic tool lubricant .
Nailer side
Regulator
Lubricator
12
) is required to
2
Compressor side
Filter
Tabla de contenido
loading

Productos relacionados para Porta-Nails 465SLT

Tabla de contenido