To ensure that the press collars function correctly, the sliding segments must be free
to move.
The sliding segments are always pressed back automatically into the correct starting
position by springs.
Ensure that marking lines (M) on shells (C) are aligned with the edges of the sliding
segments (D) when the press collar is in starting position. (Fig. 5)
If this is not the case, have the press collars repaired.
1.
Check that the nominal size of the press fitting matches the nominal size of the press
collar.
Information!
Comply with the system supplier's instructions when positioning the press collar on
the press fitting.
CAUTION
There is a risk that the press collar will break if it is positioned
incorrectly
If the press collar is positioned incorrectly on the fitting the press collar may become
damaged.
Therefore:
– The line (A) must be at the same height of the edge (B).
– If this is not the case, remove the press collar again and reposition it.
2.
Swivel the outer shells of the press collar outwards as far as possible and then position
the press collar on the press fitting.
3.
Close the press collar. (Fig. 6)
4.
Open the adaptor jaw fully using the grip.
WARNING!
Risk of injury from ejected fragments
If the adaptor jaw is positioned on the press collar incorrectly, the adaptor jaw and the
press collar may break.
Therefore
– Claws (21) of the adaptor jaw must grip pins (22) of the press collar. (Fig. 11, 12 +
13)
5.
Position the adaptor jaw on the press collar as follows.
Push claws (21) of the adaptor jaw as far as possible into grooves (24) in the press collar.
(Fig. 10)
6.
Close the adaptor jaw using the grip.