INSTALL SETTINGS 
 
 
Color Lights 
Label Aux  
Temp Calibrate 
Solar Priority 
Assign JVA 
 
 More  
 
3.5.11 Assign "HotKeys" (if present) 
 
This  menu  only  appears  if  the  optional  AquaPalm  remote  control  is  used  and  turned  on  (see  AquaPalm 
instructions). 
The AquaPalm remote has 2 hotkeys numbered "1" and "2". This menu is used to configure the function assigned 
to each one of these buttons. 
 
The "1" and "2" hotkeys on the AquaPalm remote are called "Hotkeys" in the AquaLink TRi® menu. 
 
 
INSTALL SETTINGS 
 
 
Assign Hotkeys 
Ext. SWC Power 
Diagnostics 
 More  
 
3.5.12 Zodiac® SWC Supply 
 
This menu is used to define the electric power supply source for the Zodiac® TRi salt water chlorinator if the pool 
is fitted with one. 
 
It is essential that this information be correctly entered if a TRi® chlorinator is present because it is used 
 
to link its operation to the filtering pump operation (= "Pool Mode"). 
 
INSTALL SETTINGS 
 
 
Assign HotKeys 
Ext. SWC Power 
Diagnostics 
 
 
 
 More  
 
 "None"  =    the  TRi®  is  connected  to  a  permanent  power  supply  that  is  external  to  the  AquaLink  TRi®  (or 
connected to the "input" side of one of the relays, see § 2.3.3 and § 2.3.4). 
 "Aux1" / "Aux2" / "Aux3" = the TRi® is connected and assigned to one of the 3 auxiliary relays. 
 "Filtering"  =    the  TRi®  is  connected  to  the  same  power  relay  as  the  filtering  pump  ("output"  side  of  the  first 
relay, see §2.3.3). 
 
It's recommended to use an external and permanent mains supply for Zodiac® salt water chlorinator. The 
 
parameter should consequently be set to "None". 
 
3.5.13 Troubleshooting 
 
The  "Troubleshooting"  menu  is  for  AquaLink  TRi®  maintenance.  It  is  used  to  access  the  different  internal 
programme  versions  (called  "Firmware"),  to  the  eventual  ongoing  alarms,  and  to  the  diagnosis  of  the 
communications quality between the different iAquaLink™ compatible appliances (RS485 type). 
H0369400.B.EN – 2013/03
ASSIGN JVA 
 
 
Intake                   Free 
Return                  Free 
Solar                   Used 
     
ASSIGN HOTKEYS
 
1   Aux1                        . 
2   Aux2 
 
 
 
EXT. SWC POWER
 
 
  None                       .
        
    Aux1 
    Aux2 
    Aux3 
    Filter Pump 
 
 
ASSIGN JVA
Intake 
 
  None                       .
        
    Aux1 
    Aux2 
    Aux3 
HOTKEY #1 
 
 
  Aux1                     .           
    Aux2 
    Aux3 
    Filter Pump 
    Pool Heat 
    Solar Heat 
 
 
 
 
 