Variable speed pump adjustment procedure: 
 
SET PUMP TYPE 
 
     
    1‐Speed                             
    2‐Speed 
  VSP 
VSP Setup                   > 
 
 
 Select the variable speed pump model "VS Pump Model" 
 "Speed" = selection and memorisation of the different speeds. Six choices are possible: 
- Speed 1 assigned to the "Pool Mode" 
- Speed 2 
- Speed 3 assigned to the pressure cleaner (if present) 
- Speed 4 
- Speed for heating (if a specific speed is to be assigned when heating is operating) 
- Solar speed (if there is solar heating) 
 "Assign  speed. "  =  assign  a  speed  to  each  auxiliary.  The  speed  for  the  "Pool  Mode"  is  assigned  by  default  to 
"None" because it is related to the filtering relay. One of the 3 auxiliaries can be selected for speeds 2, 3, 4 and 
heating. 
 "Priming" = choice of the speed and duration (from 1 to 5 minutes) of the pump priming mode. 
 "Min/Max"  =  minimum  and  maximum  speeds  authorised  by  the  pump.  The  default  "Min/Max"  settings  are 
respectively: 600 rpm and 3450 rpm. 
 "Anti‐freeze" = choice of the pump speed when activated in "Anti‐Freeze" mode. 
 
In some cases a specific connection cable will need to be acquired to connect a variable speed pump to the 
 
AquaLink TRi® (not supplied by Zodiac®). 
In all cases, please refer to the installation instructions supplied with the variable speed pump for all of 
its operating and safety settings. 
 
Zodiac® cannot be held liable for failure to comply with the manufacturer's instructions. 
 
3.5.6 Lighting 
 
Menu  to  configure  certain  multicoloured  LED  lighting.  Once  the  Led  lighting  has  been  assigned  to  one  of  the  3 
auxiliaries, different colours can be managed when turning on the lighting. 
 
INSTALL SETTINGS 
 
 
Color Lights 
Label Aux  
Temp Calibrate 
Assign JVA 
Ext. SWC Power 
 
 More  
 
Only  Led  lighting  compatible  with  the  list  displayed  on  the  AquaLink  TRi®  is  concerned  by  the  "Lighting" 
menu. All other types of classic incandescent bulb lighting are not concerned (basic electric connection to 
 
one of the 3 relays). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
H0369400.B.EN – 2013/03
VSP SETUP 
 
    
 
Model 
Speeds 
Assign Speeds 
Prime 
Min/Max 
Freeze 
SELECT LIGHT
 
    
 
Jandy Color 
Jandy Led                  . 
Intellibrite 
Color Logic 
 
 
 
ASSIGN TO AUX
Jandy LED 
    
 
Aux1                           JL. 
Aux2 
Aux3 
 
 
EN