ACTUAL READING
Current pH : 7,3
Setpoint : 7,2
Current ACL : 3
Setpoint : 4
If the pool is fitted with a Zodiac® TRi® salt water chlorinator connected to the AquaLink TRi®, specific menu lines
for the chlorinator will appear in the "Programming" menu :
Boost = shock‐chlorination activation for a total of 24 hours.
Low = limitation to 10% chlorine production if the cover is shut and/or wintering is active.
button when the line is highlighted to activate or deactivate the mode.
Press the
Chlorine Prod. = TRi® chlorine production setting.
The TRi® chlorine production setting is only displayed if it is a stand alone TRi® or a pH TRi (the TRi PRO has
its own chlorine production regulation).
pH/ACL reading = displays the current values and the set points for pH and ACL.
The "pH/ACL Reading" menu line only appears if the TRi® chlorinator is operating and if it is fitted with a
Tri pH or TRi PRO module. Only pH information will be displayed for a TRi® with the TRi pH module.
3.4.2 Heating system
You can activate or deactivate the heating function by managing 2 different set points. These set points are called
"Temp.1" and "Temp.2".
Zodiac
14 : 26
Pool Mode
Off
Temp1
Off
Temp2
Off
Aux1
Off
Aux2
Off
More
Heating can only start if at least one of the 2 set points is activated and the water temperature is below the active
set point. Note: approximately 1 minute will pass before the "Temp.1" or "Temp.2" set point switches from
"Auto" to "On".
The display will alternate between "26°" and "Auto" if the pool water temperature is greater than or
equal to the set point.
The display will alternate between "26°" and "On" if the water temperature is below the set point AND
"Pool Mode" is "On".
If both set points are active at the same time, the highest set point temperature will have priority.
If there is a need to immediately cut filtering, press the
equipment connected to the AquaLink TRi® will be shut down, even if a timer is running.
Zodiac
14 : 26
Pool Mode
Off
Temp1
26°
Temp2
Off
Aux1
Off
Aux2
Off
More
If you stop the "Pool Mode", the filtering will observe a 5 minute delay for the cooling of the heating
H0369400.B.EN – 2013/03
POOL HEAT
Enabled
Set To : 26°C
POOl HEAT
Enabled
Set To : 28°C
Zodiac
14 : 26
Pool Mode
Off
Temp1
26°
Temp2
Off
Aux1
Off
Aux2
Off
More
button for 3 seconds. All the pool
Zodiac
14 : 26
Pool Mode
Off
Temp1
26°
Temp2
28°
Aux1
Off
Aux2
Off
More
EN