Installation • Centrifugal Pump Suction Connection
See foundation
section.
Use pipe, tubing, or reinforced hose to make
suction connection. Hose must have sufficient
strength to resist collapse under the pressure
differential that occurs while pump is running.
Suction pipe size should be at least one commercial
pipe size larger than opening of pump inlet. Flow
velocity should not exceed 8 ft./sec.
Suction screen must screen out solids that could
clog pump impeller.
Suction screen area must be at least four times
suction pipe area.
Net Positive Suction Head Available (NPSHA)
must exceed Net Positive Suction Head Required
(NPSHR) by the pump or reduced performance and
severe pump damage may result.
All suction piping must have continuous rise to the
pump suction inlet. A 1/4 inch per foot minimum
slope is recommended.
See Pages 10 and 11 for
Swimming Pool Installation requirements.
Short length of straight pipe after reducer.
( 2 times pipe diameter minimum )
Eccentric Reducer
flat side up.
NOTICE: All connections
must be air tight.
Recommended
For Han-Dee Primer
Suction
connection, see start-up.
Gauge
Straight run, short as possible but
at least 6 times pipe diameter ("D")
after elbow to stabilize flow.
Support pipe
as required
Pipe diameter ("D")
1 x "D" minimum
from bottom
Standard or long
radius elbow.
Slope upward
to pump.
As close
as possible
4 x "D"
minimum
Strainer prevents debris
from entering pump
suction and prevents
entrapment hazard.
Strainer / Foot Valve
To keep debris from entering
Foot valve maintains
pump suction and to maintain
pump prime after shutoff.
pump prime after shut-off.