EN
Delete zone - Delete detectors/sensors in this zone.
Note: when user enters #8996#, all the wireless zone's detectors will be deleted.
Repeat zone - Alarm system will not alarm if the detectors in the repeat defense zone were triggered only
once, but if they are triggered again within 5 to 30 seconds after the first trigger, the alarm host will alert
immediately.
Note: The selection of normal zone and stay alarm zone will not influence the selection of 4, 5, 7 zone type,
it means that user can choose one zone as normal zone or stay alarm zone, meanwhile he can also choose
this zone as any of 4, 5, 7 type.
Ex:. To set 3th zone as stay alarm zone and delay zone, press #832# and #835# .
3.9. Doorbell sound type setting under disarming status
# + [04] + [1~68] + [0~3] + #
1~68 means the zone No. When you enter zone No.=99, it means this function is applied to all zones;
0~3 - is the sound type : 0=Off ; 1=Beep Beep ; 2=Doorbell sound ; 3= report entrance zone;
Under disarming status, all selected zones will sound according to the preset sound type if detector in that
zone is triggered.
Ex: . To set 9th zone to sound as door bell under disarm status, press #0492#. So when 9th zone detector is
triggered ( PIR or door detector), the system will give configured sound type of Doorbell.
3.10. System password
Input password:
*password*
Factory default password is 0000, and user can change to another 4 digit password.
This command is used for example to unlock system keybord ( if function is activated by customer).
Change password:
* + [7] + [new password] + [new password] + *
User must input new password twice to change it, and password must be 4 digit only. This command can be
used also when the keypad is locked or user forgot his password.
3.11. Password protection keypad
Function On
*11*
This function prevents other users from freely running the keyboard. Only if you enter correct password
(*password* command), the user can use the keyboard and make settings or commands. This feature has
no restrictions on remote controls and"Alarm" button on panel
If the keypad protection is enabled and no passwords is entered, the system will beep twice and ask for
unlock password to be entered with a voice message.
Note: After unlock, the keypad is locked again in 20 seconds without entering commands or keystrokes. To
access, you must enter the system password again.
Function Off
*10*
3.12 Remote control siren audio On/Off
When pressing keys on remote control, the siren would have a voice remind. User can turn On/Off this sound
alert according to their desire.
Function On:
*21*
Function Off:
*20*
3.13 Anti-crack function On/Off
Function On:
*31*
6