Trouble Shooting - continued
PROBLEM
7. Motor overload
protection "kicks out".
8. My ON/OFF air button
is not working properly?
9. The system will not
turn OFF?
10. I have adjusted the
nozzles but the flow is
weak?
11. The plastic cover is
cracked.
POSSIBLE CAUSES
a. Motor is not connected properly.
b. Low voltage due to under size
wire or low incoming voltage.
c. Wrong size heaters in protective
device.
d. Overload due to binding in pump
or wrong size impeller.
a. Control Box.
b. Air tubing.
a. Control Box Components.
a. Debris in pump casing/impeller.
b. Improper swim jet assembly.
SOLUTION
Check wiring diagram on motor.
Check with volt meter. Increase size of supply wire.
Report low supply voltage to power company. Voltage
at motor must be within 10% of motor nameplate
voltage.
Heaters should be one size larger than full load amps
shown on motor nameplate.
Indicated by high amperage readings on motor, binding
shaft. Disassemble unit and correct.
Check GFCI. If green LED does not stay ON, contact a
certified electrician to diagnose control box compo-
nents.
Check air tubing connection on the control box. Check
that the tubing is not bent or pinched. Tubing may
need to be replaced.
Press TEST button on the control box GFCI to turn off
system. Contact a certified electrician to diagnose con-
trol box components.
Check inside pump casing for any debris.
The internals may need to be removed for inspection.
To order contact the factory at 800-223-8538.