Plumbing Installation - Continued
NOTE: The BaduSteam assembly package contains all necessary parts for the installation of the unit into concrete, gunite,
liner or fiberglass pools.
CAUTION: All necessary screws and bolts included with the BaduStream are stainless steel. ALL screw threads and
threaded inserts are METRIC! ONLY METRIC bolts and nuts may be used! The two exceptions are the suction and discharge
connections on the BaduStream and pump housing (4" slip connections) and the mounting hardware for the air regulator
assembly (1/4 -20 threads). All screws should be HAND TIGHT. DO NOT use drills or pneumatic tools. DO NOT over tighten!
BaduStream II
Three Jets
Two Jets
One Jet
One Jet
* 6" pipe will allow distances of well over 50 ft. However,
control box location needs to be within 50 ft. of the ON/
OFF air button in order to function properly.
Air Regulator
Water Level
Figure 4
10
Plumbing Requirements
Pump
Distance
(2) 4 HP
10 to 30 ft.
up to 50 ft.*
4 HP
10 to 30 ft.
up to 50 ft.*
4 HP
10 to 30 ft.
up to 50 ft.*
3 HP
10 to 30 ft.
up to 50 ft.*
Vertical
Discharge Line
Horizontal
Discharge Line
4"
4"
Horizontal Suction Line
max. 30 feet with 4 " pipe
NOTE: Valves are recommended when pump is installed below water level
(flooded suction applications).
NOTE: To avoid stress on the jet housing, the jet housing and 2 to 3 inches of
plumbing stub out may be encased in gunite or concrete.
Pipe Size
Approx. Flow
4"
651 GPM
6"
651 GPM
4"
380 GPM
6"
400 GPM
4"
217 GPM
6"
217 GPM
4"
200 GPM
6"
200 GPM
Valves (Optional)
Pressure Line
Allow 12" to prevent
cavitation of the pump
4"
4"
Check Value (Optional)
(Below Water Level)
Vertical Suction Line
TDH
42 ft
42 ft
34 ft
32 ft
53 ft
53 ft
12 ft
12 ft
Service
Control Box
Disconnect
4"
Pump