WARNING:
Under no circumstances should you immerse the motor housing in
water in order to clean it. Otherwise this might result in an electric
shock or fire.
CAUTION:
• Do not use a wire brush or any abrasive items.
• Do not use any acidic or abrasive detergents.
• The single components are not dishwasher-safe.
• Wipe the casing with a damp cloth.
• You can wipe the mains adapter unit with a dry cloth.
Components 6 to 8
• These components can be rinsed off under running water.
If need be, clean the components in warm soapy water
using a soft brush.
• Allow the components to dry before you reassemble the
device.
Floor Nozzle
Refer to Fig. H to J on Page 5.
• Press the unlock button (21) to pull the floor nozzle off the
appliance holder.
• Remove threads and hair wound to the brush. Use
scissors, if required.
Storage
• Clean the appliance as described and allow it to dry.
• You can use the previously installed charging station for
storage.
• We recommend that you keep the appliance in the original
packaging if it will not be used for long periods.
• Always store the appliance out of the reach of children in a
dry, well ventilated place.
Troubleshooting
Problem
Possible cause
The device
The switch position
does not
has not been set
function.
correctly.
The rechargeable
battery is empty.
BS 1714 A CB_IM_new
Cleaning
Problem
Weak suction
power.
Noise during
operation.
Model:.................................................................BS 1714 A CB
Net weight
(only battery-powered vacuum cleaner): ..........approx. 1,24 kg
Mains adapter
Protection class: .................................................................
Input:...................................AC 100 - 240 V, 50 / 60 Hz, 0,3 A
Output: ....................................................... DC 18 V, 200 mA
Polarity:....................................................................
Battery: ..........................................10 x 1.2 V, 1800 mAh NiMH
Operating time: .................................. 20 minutes maximum
Charging time: ........................................................12 hours
The right to make technical and design modifications in the
course of continuous product development remains reserved.
This device has been tested according to all relevant current
Remedy
CE guidelines, such as electromagnetic compatibility and low
voltage directives, and has been constructed in accordance
Check the switch
with the latest regulations.
position.
Recharge the battery.
Possible cause
Remedy
The battery is near-
Charge the battery.
ly discharged.
The filters are dirty.
Clean the filters as
described under
"Cleaning".
CAUTION:
Restart operation only
with dry filters.
A foreign body has
Remove the foreign
been sucked into
body. If required,
the floor nozzle.
separate the floor
nozzle from the
appliance holder.
Technical Data
23.06.16
35