Next-Generation Tabs
LCAS Sink
MST
Generated: Indicates the actual value that is sent in the control
packets.
RS-Ack (Re-Sequence Acknowledge)
Transmitted Value: Toggle every time a RS-Ack is transmitted. The
value toggle either from 0 to 1 or 1 to 0.
Transmitted Count: Indicates the number of RS-Ack transmitted.
Generated Count: Indicates the number of RS-Ack generated by the
LCAS state machine.
Manual Toggle Count: Indicates the number of manual toggle.
Manual Control: Allows blocking the RS-Ack transmitted by the state
machine.
Toggle RS-Ack button: Allows sending a RS-Ack.
488
MST: Indicates the MST generated by the state machine.
Overwrite Enable: Allows overwriting the member status. The
status of each member having the Overwrite Enable checked can
be overwritten. Click on a specific member's drop list and select
the new status. Possible statuses are OK and Fail. The status(es)
changed will only take effect when the Apply Overwrite Value(s)
button is pressed.
Enable All: Allows enabling the MST overwrite for all members.
Apply Overwrite Value(s): Allows applying the new overwrite
value(s). This button is only available when there are overwrite
values that have not been applied.
FTB-8100 Series Transport Blazer