Waeco SinePower MSI912 Instrucciones De Montaje página 48

Ocultar thumbs Ver también para SinePower MSI912:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 89
Connecting the inverter
9.3
Connecting the 230 V power cable
(MSI1800T only)
➤ Connect the 230 Vw connection cable with safety plug to the 230 Vw in-
put jack (fig. 7 6, page 5).
➤ Connect the safety plug to the 230 V AC mains.
9.4
Connecting the 230 V output cable
(MSI1800T only)
!
WARNING!
Before connecting the 230V output cable, make sure the inverter
is switched off at the main switch.
➤ Connect the 230 Vw connection cable with safety plug to the 230 Vw out-
put jack (fig. 7 5, page 5).
9.5
Connect multiple appliances
(MSI1800T only)
The device is equipped at delivery with galvanic isolation. For the safe oper-
ation of multiple appliances, it is essential that a circuit breaker (residual cur-
rent circuit breaker) is built into the socket distribution circuit, see sample
circuit diagram in fig. 8, page 5.
Sample circuit diagram legend:
No. in
fig. 8,
Explanation
page 5
1
230 Vw power source
2
additional devices, e.g. battery charger, refrigerator
3
DC power source (battery)
4
Inverter
5
Set grounding bridge (At delivery: not set, shown by dotted
line)
6
Circuit breaker (residual current circuit breaker)
7
Socket distribution circuit for appliances
48
SinePower
EN
Tabla de contenido