7102-M004-0_B
GB
Page 33 of 116
ERGOLOCK.CB - AD - ST
11 - Connect the black pipe (Fig. 13 pos. 1) and the
blue one (Fig. 13 pos. 2) to the rapid coupling as
indicated in figure 13.
12 - Connect the main pneumatic supply by linking
connection on the machine filter unit. The main
supply hose must have a section of 10x19 (see
Fig. 14).
Fig. 14
13. Lock a 14" rim on its external flange and move the
lower part of the mounting tool against the flange of
the rim (see Fig. 15).
(Only for versions CB and AD)
Before continuing, to place two plates of the column
handling device perfectly (see Fig. 15 pos. 1).
Turn the column, which is now attached to the bead-
breaker, so that the left part of the mounting tool
has a distance of 3-4 mm from the flange of the rim.
The right side of the tool must touch the edge of the
rim.
Keeping this position, tighten the four column bolts
(Fig. 12 pos. 6) with a spanner dynamometrically
set to 65 Nm. Then re-fix the rear guard, which was
removed previously.
INSTRUCTION, USE AND
MAINTENANCE MANUAL
Fig. 15
Fig. 13
14. (Only for versions CB and AD)
15. (Only for versions CB and AD)
Fig. 16
Check that the bead-breaker turns freely on its
axis and proceed to fix it to the column support
through the lower pin, using a screw (# 203058)
and washer (# 237043). Tighten with a spanner
dynamometrically set at 70 Nm.
Opening the bead-breaker, hook the spring (#
1357000) to the two pins connected respectively
to the lower column support and the lower part
of the bead-breaker, (See Fig. 16).