Technical Data - EINHELL TK600 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
AnleitungTK 600
GB

5. Technical data

Asynchronous motor
Power rating
Idle speed n 0
Carbide saw blade
Number of teeth
Table size
Cutting height max.90°
Cutting height max.45°
Connector for dust extractor
Size, complete
Weight
Load factor:
A load factor of S2 30 min (intermittent periodic
duty) means that you may operate the motor
continuously at its nominal power level (600 W)
for no longer than the time stipulated on the
specifications label (30 minutes ON period).
If you fail to observe this time limit the motor will
overheat. During the OFF period the motor will
cool again to its starting temperature.
6. Before putting the machine into
operation
The machine has to be set up where it can stand
firmly, e.g. on a work bench, or it must be bolted
to a strong stand.
All the covers and safety devices have to be
properly fitted before the machine is switched on.
It must be possible for the saw blade to run
freely.
When working with wood that has been
processed before, watch out for foreign bodies
such as nails or screws etc.
Before you actuate the On/Off switch, make sure
that the saw blade is correctly fitted and that the
machine's moving parts run smoothly.
Before you connect the machine to the power
supply, make sure the data on the rating plate is
the same as that for your mains.
l
16
18.12.2002 18:24 Uhr
7. Assembly
Always pull out the power plug before carrying
out any maintenance or conversion work.
230 V 50 Hz
600 W S2 30 min
7.1 Fitting the saw blade (Fig. 2/3)
2950 rpm
200 x 16 x 2.4 mm
20
500 x 335 mm
43 mm
43 mm
dia. 35 mm
500 x 335 x 240 mm
14 kg
7.2 Adjusting the splitter (Fig. 4-6)
7.3 Fitting the saw blade guard (Fig. 4)
7.4 Replacing the table insert (Fig. 4)
Seite 16
Caution! Pull out the power plug.
Slacken the chip bin cover (19) by undoing the
fixing screws (20) and swing it up.
Undo the nut (21) with a ring wrench (30) on the
nut (21) and a face wrench (31) on the outer
flange (22) to apply counter-pressure.
Caution! Turn the nut in the direction of rotation
of the saw blade (4).
Take off the outer flange (22) and pull the old
saw blade (4) off the inner flange by dropping the
blade at an angle.
Clean the mounting flange.
Fit the new saw blade in reverse order.
Caution! Note the direction of rotation (see arrow
on the saw blade).
Remove the saw blade guard (2) (see 7.3).
Take out the table insert (6) (see 7.4).
Slacken the two hexagon socket-head screws
(24).
Adjust the splitter (5) so that the gap between the
saw blade (4) and the splitter (5) equals 3 - 5 mm
(see Fig. 6)
The splitter (5) has to be in line with the saw
blade (4) in longitudinal direction.
Retighten the two screws (24).
The setting of the splitter has to be checked each
time after changing the saw blade.
Mount the saw blade guard (2) on the splitter (5)
and align.
Insert the knurled screw (18) through the hole in
the saw blade guard (2) and in the splitter (5)
and secure it with the nut.
To remove the saw blade guard, proceed in
reverse order.
Caution! Pull out the power plug.
Remove the 6 screws (23).
Take off the saw blade guard (2) (see 7.3).
Lift the worn table insert (6) up and out.
Fit a new table insert in reverse order.