DESCRIPTION
BY-PASS KNOB
"Push for by-pass"
HARDNESS MIXING-KNOB
" + and - symbols"

WATER INLET

INSTALLATION OF SAMPLING-
TAPS ON THE "KIT FACILE"
MAN145
KIT FACILE - ENGLISH
FUNCTION
PUT THE SYSTEM IN BY PASS WITH "KIT FACILE": push the by-pass knob
up to the end of stroke, and turn the hardness mixing-knob counter
clockwise towards the "-" symbol up to the limit (in order to close all the
passages of water).
PUT THE SYSTEM IN WORKING POSITION (NO BY-PASS): pull the by-pass
knob outwards. If the water softener is installed, and the mixing of
hardness is done by the KIT FACILE, adjust the mixing by turning the
hardness mixing-knob toward the "-" symbol, in order to increase the
hardness value.
WATER HARDNESS MIXING BY THE MEANS OF "KIT FACILE" (WHEN A
WATER SOFTENER IS INSTALLED).
TO PUT THE "KIT FACILE" IN WORKING POSITION (NO BY-PASS), PULL THE
BY-PASS KNOB OUTWARDS BY PRESSING THE HARDNESS MIXING-KNOB.
WATER HARDNESS MIXING BY THE MEANS OF "KIT FACILE":
Turn the knob towards the "+" symbol to increase water hardness.
Turn the knob towards the "-" symbol to decrease water hardness.
TO PUT THE SYSTEM IN BY PASS WITH THE KIT FACILE, push the by-pass
knob up to the end of stroke, and turn the hardness mixing-knob counter
clockwise towards the "-" symbol up to the limit, in order to close all the
passages of water.
TO PUT THE SYSTEM IN WORKING POSITION (NO BY-PASS), pull the by-
pass knob outwards (see the instruction of the previous point "BY-PASS
KNOB").
THE INLET OF WATER CAN BE SET BOTH TO THE LEFT AND RIGHT SIDE
(OR BOTH FROM UP AND DOWN POSITION, IF THE "KIT FACILE" IS
INSTALLED VERTICALLY).
ATTENTION: The water inlet of BravoCAB water softener is to the right
side.
N.B. "KIT FACILE" allows the integrated installation of n.2 water sampling-
taps.
Frontally to the "KIT FACILE", two housings for the installation of water
sampling-taps are available (water sampling taps are not supplied with
the KIT FACILE).
The water sampling taps allow to check water values before and after the
water treatment. In order to install the water sampling-taps on the "KIT
FACILE", remove the closure stopper.