Installation with a Heater

To install the booster pump in a system with a heater, install a tee
after the filter. The tee directs a portion of the water to the booster
pump and to the heater.
Do not connect the booster pump directly to the heater; the
heated water can damage the booster pump if the heater malfunc-
tions.
Be sure to install the booster pump at least 3 feet away from the
heater to protect from excess ambient heat.
Installation with Solar Heaters
With or without a gas heater, install an in-line tee on the
return line between filter and solar heater.
This minimizes the possibility of an air lock in the booster
pump each time the solar panel fills and assures ample
water supply.
Pool Heater
Booster Pump
To Pool
To Pool Return
Installation with a Heater
Optional
From Solar Panel
Solar Heater
(Solar only)
Installation
To Solar Panel
(Solar only)
Pool Heater
Booster Pump
To Pool
To Pool Return

Installation with a Solar Heater

Installation with Pool and Spa Combination
If your pool is plumbed for a pool and spa combination, connect
the suction side of the booster pump before the spa bypass valve.
Be sure to install the booster pump at least 3 feet away from the
heater to protect from excess ambient heat. See image below
for plumbing configuration.
From Filter
Ground
Level
To Spa
Pool Return
Filter
Filter
Pump
Tee
From Pool
Filter
Filter
Pump
From Pool