Installing The Pump Hoses - Pentair BOOST-RITE Manual De Instalación / Guía Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

4

Installing the Pump Hoses

1. Cover the threads of the white colored 1" to 3/4" reducer bushing with threaded sealing tape or pipe joint compound.
2. Screw the white colored reducer bushing into the pump outlet. Hand tighten + one (1) turn with a 12" adjustable wrench. Torque = 60 in-lb
(6.8 N-m).
3. Unscrew the adapter cap from the adapter. Cover the threads with threaded sealing tape or pipe joint compound.
4. Screw the black colored adapter into the white reducer bushing. Hand tighten the adapter + one (1) and a quarter turns with a 12" adjustable
wrench.
Note: A second 12" adjustable wrench is recommended to hold the reducer bushing in place while tightening the adapter.
5. Cut the hose to the length needed to connect the booster pump to the return line. You may need to shape the hose end to round out the opening.
6. Slide the adapter cap up onto the hose. Be sure the adapter cap is up onto the hose before attaching hose to adapter.
7. Twist and push hose onto the adapter until the hose is flush with the adapter threads. Be sure the end of the hose is evenly bottomed out on
the adapter.
Note: Apply heat or warm water to help attach hose if needed (heats makes hose more flexible).
8. Screw the adaptor cap onto the adaptor to secure the hose. Hand tighten the adapter cap. Turn one (1) time with a wrench if needed.
9. Repeat steps 1-8 for both outlet and inlet hose connection. Be sure there are no tight bends or kinks when routing the hose.
Reducer bushing
Reducer Bushing (White)
BOOST-RITE
Universal Booster Pump Installation and User's Guide
Adapter
Adapter Cap
Adapter (Black)
Pump Outlet
Hose
Adapter Cap
To Pool
From Filter
Adapter (Black)
Reducer Bushing (White)
Pump Inlet
Adapter Cap
Adapter
Reducer
Bushing
Complete Hose Assembly