After Use; Cleaning And Disinfection - Spasciani RN Instrucciones De Uso

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Open cylinder valve and pressurize the set. Close cylinder valve. The pressure must never go under 20 bar per minute.
3.1.6. Check the audible warning signal
• Open the cylinder valve and pressurize the device
• Close the cylinder valve
• Unlock the locking device (pos. 1 Fig.5) by pressing on the rubber button in the middle of the demand valve cover.
• Close, with the palm of your hand, the demand valve outlet and vent the air off slowly. Watch the gauge and when
reaching a pressure of (55±5) bar, you should hear, strongly releasing, a strong sound vibration that should stop once
there is no more air in the hose. Please note: we recommend releasing the air slowly and waiting a few seconds
depending on the calibration pressures of the alarm.
• Reinsert the locking device (pos. 1 Fig.5).
3.2. Donning
Adjust the shoulder straps to their maximum length; therefore, lift the special padding
and pull on the ends of the straps. Put on the self-contained breathing apparatus and pull hard on the ends of the
shoulder straps until the backrest is comfortably leaned against your kidneys. Buckle the belt and pull on the loose
ends until achieving the desired fitting. Insert the loose ends of the shoulder straps under the belt.
Once you put on the device:
• Put on the mask and make sure it is tightly secured on the face (see the specific instructions of the mask).
• Open the valve of the cylinder, at least two turns.
• Connect the demand valve to the mask connection: at first breath, the device (pos. 1 fig. 5) unlocks and keeps a
positive pressure under the mask.
Follow the following steps to connect the demand valve to the mask:
-Type A demand valve and mask, standardized EN 148-3 (M45x3) screw connection: screw the male swivel of the
demand valve into the female one of the mask until it stops.
-Type BN demand valve and mask, bayonet connection: insert the male connection of the demand valve into the coupling of
the mask and push until the demand valve 's teeth are hooked into the appropriate tightness edge of the mask.
Please note: The connection of demand valve to the facemask must be carried out and checked by a second person.
The self-contained breathing device is now ready for use.
3.3. When using
From time to time, check the residual pressure of the air reserve with the gauge. When the pressure drops below
(55±5) bar, the alarm signal is activated. A loud sound signal will thus appear with every inhalation of air. The signal
will continue until the air reserve has been entirely exhausted. This lasts until the complete exhaustion of the air
supply. Please note: when the signal starts, the user shall leave the contaminated area. In case of emergency (greater
physical effort or increased breathing resistance), you can briefly and repeatedly act on the rubber button of the
demand valve to receive air directly into the mask.

3.4. After use

• Close the cylinder valve
• Disconnect the demand valve from the mask, let the air contained therein out and then press on the button (pos. 1 Fig.5):
- Type A demand valve and mask: unscrew the swivel of the demand valve
- Type B and BN demand valve and mask: simultaneously press on the lock buttons and disconnect the demand valve
from the mask
• Unfasten the waist belt and loosen the shoulder straps by lifting the buckle with your thumb
• Remove the mask
• Place the device on the ground without dropping it.
4. MAINTENANCE
SPASCIANI S.p.A. will not be liable for damages whenever the maintenance and repair operations were not carried out
within the establishments of its companies or by authorized third parties.

4.1. Cleaning and disinfection

Dirty parts must be cleaned after each use. Clean with warm and soapy water. Rinse with running water. Remove dust
build-ups with a damp cloth or anti-static product. Never use dry cloths and never rub any part of the PPE with wool
or non-antistatic cloths.
Please note: Follow the concentration instructions when using chemical products to disinfect the device. Avoid using
Pag. 18 / 55