Malfunction
Material leaks from
behind the paint nee-
dle sealing
Spray gun leaks from
the fluid tip ("fluid tip
aperture")
11. Disposal
Recycle the completely empty spray gun. To protect the environment, bat-
teries and residual paint have to be disposed in an appropriate way and
separately from the spray gun. Please observe local legislation!
12. After Sale Service
Your SATA dealers offers accessories, spare parts and technical support.
13. Warranty / Liability
The SATA General Conditions of Sale and Delivery shall apply and, if
applicable, further contractual agreements as well as the respective, valid
legislation.
SATA cannot be held liable especially in the following cases:
• When the operating instructions are disregarded.
• When the product is used in other than the intended ways of use.
• When untrained staff is employed.
• When no personal protection equipment is worn.
• When no original accessories and spare parts are used.
• When the product has been manipulated, tampered with or technically
modified.
• In case of normal wear and tear.
• In case when the product has been exposed to untypical shockloads
and impacts during usage.
• Assembly and disassembly.
Cause
Defective or missing
paint needle sealing.
Clogged or damaged
paint needle.
Contamination be-
tween paint needle tip
and fluid tip
Damaged nozzle set.
Corrective Action
Replace / insert paint
needle sealing, chap-
ter 9.3
Replace nozzle set,
chapter 9.1; replace
paint needle sealing, if
necessary, chapter 9.3
Clean fluid tip and
paint needle, observe
chapter 8
Replace nozzle set,
chapter 9