Aqua Medic 5000 baby ECO single 6.0 Manual De Instrucciones página 9

Ocultar thumbs Ver también para 5000 baby ECO single 6.0:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
4. Installation
Check that the sealing rings for the unions are in place.
Slot the holding plate for the venturi pump to one side of the skimmer. Push the pump on to the
holding plate and connect the pump to its union.
The PVC air tube should be fed to the top of the grey PVC pipe which is located between the two
outlet pipes to supply the venturi pump with air. This air tube must not hang down. It
should only jut out 5 cm at the top.
Connect the bottom end of the tube to the air intake of the pump.
The water inlet is located at the opposite side of the outlet pipes. Attach the union and the hose
tail (22 x 20 mm).
We recommend a pump with a capacity of 2,000 to 4,000 litres/hour (500 – 1,000 gph) e. g.
Aqua Medic Eco Runner 3700 for the water supply.
Take care that the ball valve at the bottom is closed before you start to fill the skimmer! Ensure
the availability of a sufficient quantity of usable saltwater.
The single 6.0 takes approx. 50 litres of water, the type 5000 baby ECO approx. 25 litres.
Fit the rubber sealing ring for the bayonet socket of the reaction pipe. Push the bayonet socket
into its seating and turn it to the right as far as possible. Then fit the collection cup.
The drain from the skimmer has to run freely into the aquarium. A PVC pipe (40 mm dia) can be
glued into the drain ports. It is possible to let both drains flow into one pipe but the diameter of the
pipe must not be reduced. If the drains are left separate, a reduction in pipe size to 32 mm is
possible.
The skimmer can now be filled by pumping directly from the aquarium.
Ensure, that the water level of the aquarium is not lowered too much.
-
As soon as the water level in the skimmer reaches the height of the venturi pumps, these
-
pumps should be started.
Top up with sea water as necessary.
-
After first use or after cleaning the skimmer, it takes some time for the initial foam to build up in
the reaction pipe of the collection cup. This is because the cleaned acrylic initially reacts with the
water until a build up of fatty acids naturally takes place.
After approx. 24 hours, the foam should be pushed slowly and evenly into the collection cup. The
quantity of liquid and organic substances depends on the pollution of the aquarium.
5. Maintenance
Foam cup:
Skimmer pipe: This needs only occasional cleaning, we recommend intervals from 6 to 12
Venturi pump:
Drain the water out and dismantle the pump. Flush the pump housing and air wheel with clean
water. The same should be done with the air injection nozzle. Important: The air duct in the
ceramic axle (Fig. 3, No. 1) and the boreholes in the impeller plate (Fig. 3) have to be clear.
Otherwise, the pump might be overheated that could lead to total failure.
6. Failures
Failures may arise if:
The ratio between supplied air and the water volume is not correct.
-
Cause:
The air injection nozzle is clogged or the pump chamber containing the air wheel is dirty.
Depending on the organic load the cup should be cleaned daily to weekly.
months.
The maintenance of the pump should be done at the same time as that of the
reaction pipe.
9
loading