ELECTRONIC TYING MACHINE
20. TROUBLE SHOOTING AND REPAIR
Have your power tool serviced by a qualified repair person using only identical
parts for replacement. This will ensure the safety of the power tool.
Problem
Possible reason
Battery is used up.
The equipment
Battery is not connected. Check the correct battery connection.
cannot be
started.
On/off switch failure.
Internal connecting line
Intermittent
is loose.
running.
on/off switch failure
After tying, it is loose and
not firm.
Unsuccessful tying due to
foreign material.
Tying is not
successful,
Incorrect or missing wire
tying effect is
feeding.
not good.
Tying is easily stuck by
branches.
The battery is not placed
in the charger correctly.
The connection of
Cannot charge.
charger and power
The red indicator
supply is not correct.
of charger is
Battery voltage is too low. Wait for 10 minutes.
blinking.
Battery failure .
Charger failure.
Corrective measures
Charge.
Send to the Service Centre for repair.
Send to the Service Centre for repair.
Adjust gear switch to a suitable level.
VéCheck if there are any foreign matters
in feeding track, clear up foreign matters
and unsuccessfully-tied tying wire.
1. Check if the tying wire is stuck in
feeding tray, if it is stuck, conduct
cleaning timely.
2. Check if there are any residual tying
wires or other foreign matters in the
whole feeding track, and conduct
cleaning timely.
Operation may be too fast, please adjust
operation speed. Only after confirming
the completion of tying action the tying
machine can be lifted up.
Verify battery to charger connection.
Verify correct connection of charger to
power supply.
Replace battery
Replace battery charger
80
www.kamikazevolpi.com