2.3
Charging procedure
•
Charge only GESIPA
-5°C and +55°C!
•
Take the charger out of its packaging and connect to the mains.
•
Gently insert the GESIPA
•
The charging operation starts automatically.
2.3.1 Function lights
Signal
Constant green
Flashing green
Constant red
Flashing red
Charging* takes approx. 40 minutes.
* Charging times may vary according to the remaining capacity and the battery temperature.
2.4
Battery handling
•
Only insert batteries into the charger once they have cooled down.
®
•
GESIPA
batteries can be charged approx. 1000 times.
•
Do not insert the battery into the charger after each use.
Ifbatteryautonomybecomessignificantlyshorterdespiteproperrecharging,thebattery
•
should be replaced.
•
Store batteries in a dry place where there is no danger of frost. The optimum operating
temperature range is 10°C to 50°C.
®
GESIPA
batteries have a display showing battery life in percent. Press the button in the
display to activate the green LED lights for approx. 5 seconds.
*****
Battery fully charged
****
Battery capacity approx. 80%
***
Battery capacity approx. 60%
**
Battery capacity approx. 40%
*
Battery capacity max. 20%, charge soon