Product Overview; Description/Intended Use - Dräger Panorama Nova P Instrucciones De Uso

Ocultar thumbs Ver también para Panorama Nova P:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
2
Description
2.1

Product overview

6
5
4
3
2
1
12
11
10
1
Button
2
Check valve
3
Inner mask
4
Visor
5
Visor frame
6
Upper head-harness
connector
14
7
8
9
7
Harness
8
Face seal
9
Mask body
10 Clamping ring
11 Exhalation valve cover
12 Equipment connector
(approved by Dekra Exam)
2.2

Description/Intended use

The full-face mask protects the face and eyes from hostile media.
Mask spectacles are available for users who wear spectacles.
Temperature during operation -30 °C to +60 °C.
The full-face mask has a plug-in connector. It may only be used with
approved positive pressure compressed air breathing apparatus or
positive pressure hose breathing respirators.
2.3
Approvals
The full-face masks are facepieces conforming to EN 136 CL. 3 and
carry the CE mark. In addition, they meet the requirements of flame
engulfment in accordance with EN 137 and the requirements of the
PPE guideline 89/686/EEC.
The full-face masks have been tested in accordance with 94/9/EC for
use in potentially explosive atmospheres and meet the following
protection classes:
Full-face masks with visors marked with "L":
I M1
I M1
1)
II 1 G IIC T6
II 1 G IIB T6
II 1D
II 1D
1)
-30 °C ≤ Ta ≤ +60 °C
Full-face masks with visors marked with "PC" or "PC/CC":
I M1
I M1
1)
II 1 G IIB T6
II 1 G IIA T6
II 1D
II 1D
1)
-30 °C ≤ Ta ≤ +60 °C
I M1
1)
1)
II 1 G IIA T6
II 1D
1)
Panorama Nova P