BIP LD2-T017-04-BP _ _ / BP _ _ -S4
Inductive Positioning System
6
IO-Link interface (continued)
Returning measuring range settings to factory
default
1. Activate the measuring range settings
(address 0xC0/192
).
10
2. Return all measuring range settings to the factory settings
1)
See chapter Factory settings on page 17
6.13
Factory settings
The following settings exist at the time of delivery and after
resetting to factory settings:
Binary data channel factory settings
Parameters
Setpoint SP1
Setpoint SP2
Switch point mode
Switch point logic
Switch point hysteresis
Tab. 6-12: Factory settings (binary data channel)
Measuring range factory settings
Parameters
Index
Hex.
Dec.
Slmin
00C8
200
Slmax
00C8
200
Inversion
00C5
197
Tab. 6-13: Factory settings (measuring range)
Reset to factory settings
All sensor parameters can be reset together.
To reset the settings separately, see Returning all switching
channel settings to factory default on page 16 or
Returning measuring range settings to factory default on
page 17.
► Return all settings (BDC and measuring range) to factory
default.
www.balluff.com
BDC1...3
Comment
Hex.
Dec.
0000
0
Switching threshold value
0000
0
Functionally not supported
00
0
Inactive
00
0
Switching state NO (normally open)
0064
100
Default value corresponds to a digital output value of 100.
Subindex
Data
format
Hex.
Dec.
01
1
UINT16
02
2
UINT16
00
0
UCHAR8
Index
Subindex
Hex.
Dec. Hex.
003A
58
00
.
0002
2
00
1)
Default value
Comment
Hex.
Dec.
0000
0
Starting point of curve
0FFF
4095
End point of curve
00
0
Non-inverted curve
Index
Subindex
Hex.
Dec. Hex.
0002
2
00
Access
Value
Dec.
0
Write only
0xC0
0
Write only
0x4E
Access
Value
Dec.
0
Write only
0x82
english
17