BIP LD2-T017-04-BP _ _ / BP _ _ -S4
Inductive Positioning System
6
IO-Link interface (continued)
6.5
System parameters
Index
Parameters
Hex. Dec.
000D 13
Profile
characteristic
000E 14
PDInput
descriptor
Tab. 6-6:
System parameters
6.6
Sensor-specific parameters
Index
Parameters
Hex.
Dec.
0052
82
Internal temperature 00
0056
86
COMx speed
00C0
192
Gradient
00C1
193
Offset
00C5
197
Inversion
00C8
200
Slmin[μm]
Slmax[μm]
1) Please note that floating point values have Little-Endian coding and start with the LSB.
2) Curve inversion deletes any previously set switching points.
Tab. 6-7:
Sensor-specific parameters
12
english
Subindex
Parameters
Hex. Dec.
01
1
DeviceProfileID
02
2
FunctionClassID
03
3
FunctionClassID
04
4
FunctionClassID
01
1
BDC1,BDC2,
BDC3
02
2
PDV1
03
3
PDV2
Subindex
Data format
(length)
Hex. Dec.
0
Char (1 byte)
00
0
Char (1 byte)
00
0
Float32
00
0
Float32
00
0
UChar (1 byte)
01
1
UINT16 (2 bytes)
02
2
UINT16 (2 bytes)
Data format
Access
UINT16
Read only 0x0001
OctetStringT3 Read only 0x010300 Switching channel
Access
Value
range
Read only
–128...+127 Output of all
Read only
2
(4 bytes) Read only
1)
(4 bytes) Read only
1)
Read/Write 0x00-0x01
Read/Write 0...4095
Read/Write 0...4095
Value
Comments
range
Smart Sensor
Profile
0x8001
Binary data channel
0x8002
Process value
0x8004
Teach channel
0x010103 Out of Range
0x020C04 Position value
Comments
temperature
parameters (in °C)
IO-Link COM speed
Gradient of curve
(output → distance)
Curve offset
(output → distance)
Curve inversion
2)
Current value for
Slmin[μm]
Current value for
Slmax[μm]