Festool TURBO II M - 8 WP R1 Manual De Instrucciones página 23

Turbina de aspiración
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 41
Failure code
Warning D
E
W1.1
Temp. high
W1.2
Temp. high
W1
Flow
W3
PWD user
W4
Service!!
W5
FI temp. high Flashes 3
W6
ON button
W9
Empty
In the case of warnings the Warning LED [1-6] flashes yellow on the control panel, and the external light to
be connected to the control system by the customer flashes according to the table above; the system con-
tinues to run. A warning message is displayed. If the cause of the warning is eliminated, the LED or Warning
light goes off. The warning message remains for a few minutes and disappears again. Warning messages
can be deleted by confirming with the [1-5] button.
Resetting the counter for the maintenance interval is only possible by service personnel.
Failure messages on the display
Extraction unit goes to Sleep mode. Start-up is not possible. Failure LED [1-7] lights up red on the control
panel and the external warning light to be connected to the control system by the customer lights up (steady
light). The LED or Failure light goes off when the cause of the failure disappears.
A failure message is displayed which can be deleted using the [1-5] button.
Additional text (Servicetext) is displayed which can be individually defined (see chapter 8.7). Recommenda-
tion: For example, enter the telephone number of the responsible service company here.
Failure code
Failure D
E
F1
Container
F1
Temp. high
Warning
Significance
light
Flashes 3
High motor temperature
times - Pause
Extraction unit runs at
reduced power
Flashes 3
High temperature on blower
times - Pause
nozzle
Extraction unit runs at
reduced power
Regular flash-
Volume flow below 20 m/s
ing
Flashes once
System is located in the fac-
- long pause
tory menu
Flashes once
Maintenance interval
- long pause
exceeded
High temperature on the fre-
times - Pause
quency inverter, extraction
system running at lowest
speed
Flashes 3
Switch-on button was pressed
times - Pause
<1 min or is jammed.
Flashes once
Container full
- long pause
Significance
Container not inserted or inserted
incorrectly or fault with container
switch
Temperature in motor winding too
high
Turbo II M
Solution
Provide improved cooling.
Provide improved cooling.
Reduce permissible number
of workstations.
Replace filter.
Switch off the device at the
main switch or wait 60 s
without input.
Contact Service.
Carry out maintenance.
Provide improved cooling.
Press switch-on button
again.
Contact Service.
Empty container (see chap-
ter 8.5 and 10.1).
Solution
Check container.
Check/replace container switch.
If the problem recurs, contact Ser-
vice.
Contact Service.
GB
23
Tabla de contenido
loading

Productos relacionados para Festool TURBO II M - 8 WP R1

Este manual también es adecuado para:

Turbo ii m - 8 wp r1 atexTurbo ii m - 14 wp r1Turbo ii m - 14 wp r1 atex

Tabla de contenido