Troubleshooting

SYMPTOM
POSSIBLE CAUSE(S)
Motor will not run
Disconnect switch is off
Fuse is blown or circuit breaker tripped
Starting switch is defective
Wires at motor are loose,
disconnected, or wired incorrectly
Pressure switch contacts are dirty
Motor runs hot and
Motor is wired incorrectly
overload kicks off
Voltage is too low
Pump cycles too frequently
Motor runs but no
Pump in new installation did
water is delivered*
not pick up prime through:
1. Improper priming
2. Air leaks
3. Leaking foot valve or check valve
* (Note: Stop pump;
Pump has lost prime through:
then check prime
1. Air leaks
before looking for
2. Water level below suction pipe inlet
other causes.
Unscrew priming
Foot valve or strainer is plugged
plug and see if water
Ejector or impeller is plugged
is in priming hole).
Check valve or foot valve is stuck shut
Pipes are frozen
Foot valve and/or strainer are
buried in sand or mud
Water level is too low for shallow well
setup to deliver water
Pump does not
Water level in deep well is lower than
deliver water to full
estimated
capacity
Steel piping (if used) is corroded or
limed, causing excess friction
Piping is too small in size
Pump delivers water but
Pressure switch is out of adjustment or
does not shut off or
contacts are welded together
pump cycles too
Faucets have been left open
frequently
Venturi, nozzle or impeller is clogged
Water level in deep well is lower than
estimated
Standard pressure tank is waterlogged
and has no air cushion
Pipes leak
Foot valves leak
Air charge too low in pre-charged tank
Air spurts from faucets
Pump is picking up prime
Leak in suction side of pump
Well is gaseous
Intermittent over-pumping of well.
(Water drawn down below foot valve.)
For parts or assistance, call Simer Customer Service at
CORRECTIVE ACTION
Be sure switch is on
Replace fuse or reset circuit breaker
DISCONNECT POWER; Replace starting switch
Refer to instructions on wiring (Pages 8 and 9). DISCONNECT POWER;
check and tighten all wiring.
Capacitor voltage may be hazardous. To discharge
capacitor, hold insulated handle screwdriver BY THE HANDLE and
short capacitor terminals together. Do not touch metal screwdriver
blade or capacitor terminals. If in doubt, consult a qualified electrician.
DISCONNECT POWER and file contacts with emery board or nail file.
Refer to instructions on wiring
Check with power company. Install heavier wiring if wire size is too small
(See Electrical / Wiring Chart).
See section below on too frequent cycling
In new installation:
1. Re-prime according to instructions
2. Check all connections on suction line, AVC and ejector
3. Replace foot valve or check valve
In installation already in use:
1. Check all connections on suction line and shaft seal
2. Lower suction line into water and re-prime. If receding water level
in well exceeds suction lift, a deep well pump is needed.
Clean foot valve or strainer
Clean ejector or impeller
Replace check valve or foot valve
Thaw pipes. Bury pipes below frost line. Heat pit or pump house.
Raise foot valve and/or strainer above bottom of water source.
Clean foot valve and strainer.
A deep well jet package may be needed (over 25 ft. to water) to
deliver water
Replace nozzle and venturi with correct combination for the well; lower
the ejector to correct level in the well
Replace with plastic pipe where possible, otherwise with new steel pipe
Use larger piping
DISCONNECT POWER; adjust or replace pressure switch
Close faucets
Clean venturi, nozzle or impeller
Replace nozzle and venturi with correct combination for the well
Drain tank to air volume control port. Check AVC for defects. Check for
air leaks at any connection.
Check connections
Replace foot valve
DISCONNECT POWER and open faucets until all pressure is relieved
Using tire pressure gauge, check air pressure in tank at valve stem
located on the tank. If less than pressure switch cut-in setting (30-50
PSI), pump air into tank from outside source until air pressure is 2 PSI
less than cut-in setting of switch. Check air valve for leaks (use soapy
solution) and replace core if necessary.
When pump picks up prime, all air will be ejected
Suction pipe is sucking air. Check joints for leaks.
Consult factory about installing a sleeve in the well
Lower foot valve if possible, otherwise restrict pump discharge