FUNCTIONAL DETAILS / TECHNICAL DATA
Type of operation:
Operating mode:
Operating temperature:
Measured temperature:
Temperature probe:
Measurement accuracy:
Preset programs:
Resolution hourly programming:
Max. n° of temperature changes:
Temperature levels:
Temperature set point resolution:
Antifreeze temperature:
Manual temperature:
Differential regulation:
Party function:
Holiday function:
Temporary temperature forcing:
Thermal gradient self-learning:
Unit of measure:
Interval between two successive measurements: 1 minute
Remote control:
Batteries discharged signal:
Radio frequency:
Radio range:
Supply:
Stand-by charge:
Max. dimensions (B x L x H):
heating and air conditioning
automatic, manual and antifreeze
-5° ÷ +45°C
0 ÷ +45°C
NTC, 100K at 25°C
±0.5°C at 20°C
2 weekly programs
(heating and air conditioning)
15 minute
4 per hour
3 levels (T1-T2-T3) programmable
from 5 to 40°C differentiated
between air conditioning and heating
0.1° C
adjustable from 2 to 7°C
adjustable from 5 to 40°C
adjustable from 0.2 to 2°C
timed from 1 to 23 hours
timed from 1 to 99 days
settable
selectable, with max. advance of 2 hours
°C or °F
with the GSM code GW 90 821 remote control
unit (not included)
with symbol on the display
868 MHz
100 m in a free field
2x1.5V type AAA alkaline batteries
2 minutes for battery replacement
120x92x19mm