With a high solid content or with filamentous par
ticles use only the free-flow (vortex) EDV, EGT,
EGF. construction.
GB
- Maximum liquid temperature: 35 °C.
- Maximum liquid density: 1100 kg/m
- Minimum
dimensions
0.55x0.55m; depth 0.5 m.
- Minimum immersion depth see also sections 6.5.,
6.6.
- Maximum submersion depth 5 m.
For outdoor use the power supply cable must have
a length of not less than 10 m.
2.2 Improper use
The device is designed and built only for the purpose
described in paragraph 2.1.
Do not use in garden ponds, tanks or
swimming pools when people are in the
water.
The Pump cannot be used in explosive or
XXXXXXX
flammable environments.
Q min/max X/X m
Improper use of the device is forbidden, as is
H max/min X/X m
X kW (XHp)
use under conditions other than those
220∆/380Y V3~50Hz
indicated in these instructions.
X/X A
Improper use of the product reduces the safety and
XXXXXXXX
the efficiency of the device, Vertical S.r.l. shall not be
responsible for failure or accident due to improper
use.
2.3 Marking
The following picture is a copy of the name-plate that
is on the external case of the pump.
1
Pump XXXXX
2
Q
XX-XX l/min
3
H min XX m
8
Motor
5
XXXXX V
Continuos Duty
Capacitor XX
1 Pump type
2 Delivery
3 Head
4 Rated power
5 Tension nominale
6 Nom. motor current
Capacitor
7
3 TECHNICAL FEATURES
3.1 Technical data
Dimensions and weight (paragraph 12.1).
Nominal speed 2900/3450 rpm
Protection IP X8
Supply voltage / Frequency
230V 1~ 50 Hz
220V 1~ 60 Hz
Sound pressure at minimum immersion depth: < 70
dB (A).
Page 10 / 80
3
.
of
installation
Made in Italy
XXXXXXX
/h
3
XX
IP
n XXXX/min
S.F.
cosø X
S1 l.cl. X X kg
16
Made in Italy
15
N° XXXXXXX
3
H XX-XX m
3
H max XX m
4
~
X
XX Hz
P1 XX kW
XX A
Tmax °C
6
Cl XX IP 68
uF XX
V
7
10
14
8 Fréquence
10 Insulation class
14 Protection
15 Serial number
16 Certifications
230V - 400V 3~ 50 Hz
220V - 380V 3~ 60 Hz
Noise disappears when the pump is submersed.
Maximum starts/hour: 30 at regular intervals.
4 SAFETY
pit:
4.1 General provisions
Before using the product it is necessary to
know all the safety indications.
Carefully read all operating instructions and
the indications defined for the different steps:
from transportation to disposal.
The specialized technicians must carefully
comply with all applicable standards and laws,
including local regulations of the country
where the pump is sold.
The device has been built in conformity with
the current safety laws. The improper use
could damage people, animals and objects.
The manufacturer declines any liability in the
event of damage due to improper use or use
under conditions other than those indicated on
the name-plate and in these instructions.
Follow the routine maintenance schedules
i
and the promptly replace damaged parts, this
will allows the device to work in the best
conditions.
Use only original spare parts provided from
Vertical S.r.l. or from an authorized distributor.
Don't remove or change the labels placed on
the device.
Do not start the device in case of defects or
damaged parts.
Maintenance operations, requiring full or
partial disassembly of the device, must be
done only after disconnection from the supply.
4.2 Safety devices
The device has an external case that prevents any
contact with internal parts.
4.3 Residual risks
The appliance, designed for use, when used in-line
with the design and safety rules, doesn't have resi-
dual risks.
4.4 Information and Safety signals
For this kind of product there will not be any signals
on the product.
4.5 Individual protection devices
During installation, starting and maintenance it is
suggested to the authorized operators to consider the
use of individual protection devices suitable for
described activities.
During ordinary and extraordinary maintenance inter-
ventions, where it is required to remove the filter,
safety gloves are required.
ED, EG Rev. 2 - Operating Instructions