Measurement
Max. permissible standard deviation
inaccuracy
according to clinical testing:
systolic 8 mmHg /diastolic 8 mmHg
Memory
2 x 60 memory spaces
Dimensions
L 72 mm x W 69 mm x H 60 mm
Weight
Approx. 101 g (without batteries)
Cuff size
135 to 195 mm
Permissible operating
+5 °C to +40 °C, 15 to 93% relative air
conditions
humidity (non-condensing)
Permissible storage
-25 °C to +70 °C, ≤ 93 % relative air
conditions
humidity, 700 –1060 hPa ambient pres-
sure
Power supply
2 x 1.5 V
Battery life
For approx. 250 measurements,
depending on the blood pressure level
and/or pump pressure
Classification
Internal supply, IP21, no AP or APG,
continuous operation, type BF applied
part
The serial number is located on the device or in the battery
compartment. Technical information is subject to change with-
out notification to allow for updates.
• This unit is in line with European Standard EN 60601-1-2 (in
accordance with CISPR 11, IEC 61000-4-2, IEC 61000-4-3,
IEC 61000-4-8) and is subject to particular precautions with
regard to electromagnetic compatibility (EMC). Please note
AAA batteries
23
that portable and mobile HF communication systems may
interfere with this unit.
• This device is in line with the EU Medical Devices Directive
93/42/EEC, the „Medizinproduktegesetz" (German Medical
Devices Act) and the standards EN 1060-1 (non- invasive
sphygmomanometers, Part 1: General requirements),
EN 1060-3 (non-invasive sphygmomanometers, Part 3: Sup-
plementary requirements for electro-mechanical blood pres-
sure measuring systems) and IEC 80601-2-30 (Medical elec-
trical equipment – Part 2 – 30: Particular requirements for the
safety and essential performance of automated non-invasive
blood pressure monitors).
• The accuracy of this blood pressure monitor has been care-
fully checked and developed with regard to a long useful life.
If using the device for commercial medical purposes, it must
be regularly tested for accuracy by appropriate means. Pre-
cise instructions for checking accuracy may be requested
from the service address.

11. Warranty / service

Beurer GmbH, Söflinger Straße 218, 89077 Ulm, Germany
(hereinafter referred to as "Beurer") provides a warranty for this
product, subject to the requirements below and to the extent
described as follows.
The warranty conditions below shall not affect the seller's
statutory warranty obligations which ensue from the sales
agreement with the buyer.
The warranty shall apply without prejudice to any manda-
tory statutory provisions on liability.