Minipack-Torre Galileo Manual De Usario página 22

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 54
Chapter 6. Machine adjustment and setting up
Through button (S) it is possible to look through the variables of the selected program, while through buttons (2) and (3)
the memorized values can be modified. These buttons (2) and (3) act by one digit at a time, but if they are held down for
more than a second, the value will rapidly increase or decrease.
To validate modifications, press button (S) until the number of the program appears on the display.
The fan delay time after sealing can be modified; there is not a LED indicating this variable which is shown with an "r" on
the left display, whereas the two remaining digits will indicate the set up time.
At the end of all variables to be adjusted, the display will show the code of the program just chosen (for example P01).
Note: If the hood is closed during the programming phase, the machine will not work.
Once all adjustments have been made, the machine is ready to start working.
Variable
Sealing time
(values expressed in seconds)
Fan delay time after sealing
(values expressed in seconds)
Shrinking time
(values expressed in seconds)
Heat chamber temperature
the indicated value will correspond to:
0 = 0° (the heating element is switched off)
1 ... 150 = 100° ... 398°C (2°C each point)
CYCLE COUNTER
When the machine is in the PROGRAMS SELECTION mode, the display will show the programme that is being run (e.g.
"P01").
In this mode, press button (P) to activate the "cycle counter" function".
The display indicates the number of cycles since the machine was switched on.
Then, press and hold buttons (2), (3) and (S) simultaneously for 3 seconds to activate the "totalizer" function.
The display indicates a figure corresponding to the total number of cycles performed by the machine, expressed in
thousands.
Starting from the right, the numbers that appear on the display indicate:
st
1
number = thousands of cycles
nd
2
number = tens of thousands of cycles
rd
3
number = hundreds of thousands of cycles
Press button (2) again and the display indicates a number corresponding to the units.
The display indicates a figure corresponding to the total number of cycles performed by the machine, expressed in units.
Starting from the right, the numbers that appear on the display indicate:
st
1
number = single cycles
nd
2
number = tens of cycles
rd
3
number = hundreds of cycles
Press button (2) again to return to the "cycle counter" function.
Finally, press button (P) to return to normal operation (the display shows the current programme).
Shrinking time
6"
5"
4"
3"
2"
TABLE OF PARAMETERS ACCORDING TO PROGRAMMES
Min. = 0,0
Max. = 3,0
Default = 1,3
not settable
not settable
not settable
APPROXIMATE TABLE OF MACHINE CICLE ADJUSTEMENT
P1
(sealing only)
Pause time
6"
7"
8"
9"
10"
21
P02, 03, 04, 05, 06, 07, 08, 09, 10
(sealing and shrinking)
Min. = 0,0
Max. = 3,0
Default = 1,3
Min. = 0,0
Max. = 1,0
Default = 0,0
Min. = 0,0
Max. = 10,0
Default = 2,5
Min. = 0
Max. = 150
Default = 120
Heat chamber temperature
(value indicated on the display)
100
110
120
130
140
EN
Tabla de contenido
loading

Este manual también es adecuado para:

Galaxy

Tabla de contenido