Air Turbulation Strips
& Vent
SENTINEL HEATERS: Assemble the strips and insert
into last tube, see Fig. 10. Edge of strip is fl ush with
end of tube.
OVAL 80 HEATERS: Both strips are
factory installed into the oval tube. At
installation, ensure strips are snugly fi t
into oval tube and do not extend past
end of tube.
FIG. 10
REGARDLESS OF TUBE DESIGN:
-- Ensure the green clip is installed on the exhaust vent.
See Fig. 11.
-- Insert the exhaust vent to the end of the last tube.
-- Push the exhaust vent until the tube is stopped at
the rivet.
FIG. 11
GREEN
CLIP
Oval 80 v.2 and Sentinel v.2
INSERT STRIP ASSEMBLY
INTO LAST 10 FT. OF TUBE
OUTLET END
Owner's Manual • Oval 80 v.2 and Sentinel v.2
Radiant Tube Heaters

Sediment Trap Assembly

Assemble the tee, nipple, and cap to the nipple at the
gas inlet of the heater. See Fig. 12. Use a wrench to
hold the pipe nipple when installing the sediment trap.
Tighten securely. The sediment trap assembly must
always be mounted in a vertical position. Check all
connections for gas leaks using approved gas leak
detectors.
FIG. 12
NIPPLE
TO GAS CONTROL VALVE INLET
Manual Shut-off Valve,
Hose & Regulator
1. Assemble the components together. See Fig. 13.
This view shows general assembly of the compo-
nents. The regulator must always be mounted so its
vent, regardless of location on the regulator, is al-
ways pointed downward. Ensure hose is positioned
away from the heater.
2. Tighten all connections securely and check
for gas leaks
FIG. 13
REGULATOR VENT
TO CONTROL
VALVE INLET
15
TEE
NIPPLE
CAP
REGULATOR
NIPPLE
VALVE, MANUAL
SHUT-OFF
GAS HOSE
ADAPTER
SEDIMENT TRAP