18. Do not exceed input rating stamped on the
dataplate of the heater. Do not exceed the burner
manifold pressure stated on the dataplate. Do
not use an orifi ce size different than specifi ed for
the specifi c input rating of this heater, fuel type
confi guration and altitude.

Initial Setup

1. Plan the installation. Determine location for the heater
to optimize its heat pattern, keeping in mind cooler
regions in the house (end walls, and curtains) and
clearances to combustibles.
2. Hang the burner box. See Fig. 5. Maintain clearances
to combustibles as shown in Fig. 1.
3. From the burner box chain, measure the distances
shown in Fig. 6 or 7 depending on if a Sentinel or
Oval 80 heater is being installed. Aligning to the
center of the burner box discharge, hang
chains at these points, using open eye hooks.
FIG. 5
JOIST
OPEN EYE HOOKS
IN LINE WITH
EYE BOLTS ON
BURNER BOX
OPEN EYE BOLT
1Ft.
.30m
BURNER
DISCHARGE
Owner's Manual • Oval 80 v.2 and Sentinel v.2
Radiant Tube Heaters
FIG. 6 SENTINEL
A
B
TRUSS
CENTERS
4 FOOT
5 FOOT
10 FOOT
* A SUPPORT MUST BE CREATED BETWEEN THE TRUSSES
FIG. 7 OVAL 80
A
B
TRUSS
CENTERS
4 FOOT
5 FOOT
10 FOOT
* A SUPPORT MUST BE CREATED BETWEEN THE TRUSS

Hanging the Tubes

Refer to Fig. 8 (on next page) and the following instructions:
1. Slide a tube clamp over the non-swaged end of the 10 ft.
bright aluminized tube. One aluminized tube per tube kit.
2. Install the tube over the swaged discharge tube on the
burner box:
TIGHTEN HOOKS
SECURELY
a. Tube weld seam must be down.
b. Non-swaged end of tube must be complete-
ly pushed over swaged end of adjoining
tube.
c. Clamp must be centered over tube
connection.
d. Clamp bolts must be up.
e. Clamp bolts must be tight.
-- Tighten both bolts fi rmly.
-- Tighten both bolts to 35 ft.-lbs.
-- Finish tightening bolts:
-- Sentinel Heaters: Finish tightening bolts
to 65 ft. lbs.
-- Oval 80 Heaters: Finish tightening bolts
to 44-59 ft. lbs.
BURNER BOX
HANGING CHAINS
C
D
E
HANGING CHAIN DISTANCES
HEATER
A - B B - C C - D D - E E - F F - G
LENGTH
(FT)
(FT)
(FT)
30 FOOT
4
4
12
40 FOOT
4
4
12
50 FOOT
4
4
12
30 FOOT
5
5
10
40 FOOT
5
5
10
50 FOOT
5
5
10
30 FOOT
5
*
5
10
40 FOOT
5
*
5
10
50 FOOT
5
*
5
10
BURNER BOX
BURNER BOX
HANGING CHAINS
C
D
HANGING CHAIN DISTANCES
HEATER
A - B B - C C - D D - E
LENGTH
(FT)
(FT)
20 FOOT
4
50 FOOT
4
4
4
50 FOOT
20 FOOT
5
5
5
5
20 FOOT
50 FOOT
5
5*
5
5
*
F
G
(FT)
(FT)
(FT)
8
8
12
8
12
8
10
10
5
10
10
5
10
10
5
*
10
10
5
*
HANGING CHA
E
F
(FT)
(FT)
12
8
4
8
5
10
5
10
10
5*
10
5