3. Proper use
The compressor is designed to generate com-
pressed air for compressed air driven tools.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
Mains connection: .................. 220-240 V ~ 50 Hz
Motor rating: ................................1.1 kW S3 15%
Idling speed n0 (pump) .......................3750 min
Idling speed n0 (motor) .....................15000 min
Operating pressure bar: ............................ max. 8
Theoretical suction rate l/min.: ...................... 180
Output (compressed air) at 7 bar: .... 10 liters/min
Output (compressed air) at 4 bar: .... 36 liters/min
Sound power level LWA in dB: ......................... 96
Uncertainty KWA ....................................... 1.9 dB
Sound pressure level LpA in dB: ..................... 74
Uncertainty KpA ........................................ 1.9 dB
Protection type: ............................................ IP20
Weight of the unit in kg: ................. approx. 5.3 kg
Protection class:............................................. II/
Danger!
Sound and vibration
Sound and vibration values were measured in
accordance with EN ISO 2151: 2008.
Operating mode S3 - 15% - 10min: S3 = Inter-
mittent mode without infl uencing the starting pro-
cess. This means that during a period of 10 min
the max. operating time is 15% (1.5 min).
Anl_TC_AC_180_8_OF_SPK9.indb 22
Anl_TC_AC_180_8_OF_SPK9.indb 22
GB
5. Before using the equipment
Before you connect the equipment to the power
supply make sure that the data on the rating plate
are identical to the supply voltage.
•
Check the equipment for damage which may
have occurred in transit. Report any damage
immediately to the transport company which
was used to deliver the compressor.
•
Install the compressor in the vicinity of the
point of consumption.
•
Avoid long air lines and supply lines (extensi-
on cables).
•
Make sure that the intake air is dry and dust-
free.
•
Do not install the compressor in a damp or
wet room.
•
The compressor may only be used in suitable
rooms (with good ventilation and an ambient
temperature from +5 °C to 40 °C). There must
be no dust, acids, vapors, explosive gases or
inflammable gases in the room.
-1
•
The compressor is designed to be used in dry
-1
rooms. It is prohibited to use the compressor
in areas where work is conducted with spray-
ed water.
•
Operate the equipment only on a firm, level
surface.
•
During operation place the compressor on the
rubber feet on the back of the compressor.
•
Important! When you switch off the compres-
sor, excess air will escape at the safety valve.
This is not a fault, but arises in connection
with the equipment's construction.
6. Operation
6.1. Mains connection:
Before you use the machine, make sure that the
mains voltage complies with the specifi cations on
the rating plate. Long supply cables, extensions,
cable reels etc. cause a drop in voltage and can
impede motor start-up. At low temperatures below
+5°C, sluggishness may make starting diffi cult or
impossible.
6.2 On/Off switch (4)
To switch on the equipment set the On/Off switch
(4) to position 1.
Move the On/Off switch (4) to position 0 to switch
off the equipment.
- 22 -
21.01.2019 08:35:01
21.01.2019 08:35:01