EXISTING CONSTRUCTION (BELOW CEILING APPLICATION) INSTALLATION INSTRUCTIONS
5. Place two clips (BB) along the bottom edge of each
side of the housing (A). Place the housing (A) into the
opening, then mount the housing (A) to the joist.
Note: The clips (BB) will ensure the bottom edge of the
housing (A) is flush with the ceiling board.
Hardware Used
eclip
~
x4
6. Use long screws (AA) to screw the housing (A) directly
to the joist using keyhole mounting tab holes or holes on
the inside of the housing (A). Choose the side that best
works for the installation area. One side of the housing
(A) has a foam insert. Remove and discard this foam
insert when choosing that side.
Note: The bottom edge of the housing (A) must be flush
with the finished ceiling.
Hardware Used
Long Screw
Ol)))lll))l
ll\)1 ))))) I)))\)
0>
x
3
or 4
7. Connect the wiring according to the wiring diagram.
a. Connect the black wire from the fan to the black wire from
the fan switch with two-port quick connect (GG).
b. Connect the black wire from the light to the black wire from
the light switch with two-port quick connect (GG).
c. Connect the white wire from the fan to the white wire from
the light and connect to the line in from the ceiling with
three-port quick connect (H H).
d. Connect the ground/green wire from the unit to the ground
wire in the ceiling with two-port quick connect (GG).
Note: For single wall switch applications, remove and cut
the clear 2 port
connectors
from the 2 black wires
coming from the bath fan chassis. Strip 1/2 in. of
insulation from the wire ends and connect both black
wires to the single black wire coming from the ceiling/
switch.