Internal Diagnostics
Code
Message
Remedies
Pr1
Cabinet
•
probe error
•
•
•
Pr2
Pin probe
•
error
CK640_ML_A5_v4_20200728.indb 15
CK640_ML_A5_v4_20200728.indb 15
Consequences
See P0
Consequences if the error occurs while in "stand-by" mode:
parameter
•
If parameter C11 is set to 0, it will not be possible to start
Check probe
any of the cycles
integrity
•
If parameter C11 is set to 1, the pin probe will function as
Check probe-
the cabinet probe and only timed cycles will be allowed to
device
start
connection
Consequences if the error occurs during a timed chilling
Check the
operation:
cabinet
•
If parameter C11 is set to 0, the cycle will be interrupted
temperature
•
If parameter C11 is set to 1, the pin probe will function as
the cabinet probe and the chilling operation will continue
Consequences if the error occurs during a set-temperature
chilling operation:
•
If parameter C11 is set to 0, the cycle will be interrupted
•
If parameter C11 is set to 1, the pin probe will function
as both the cabinet probe and pin probe and the chilling
operation will continue
Consequences if the error occurs during a storage operation:
•
Parameter C11 is set to 0, the compressor activity will
depend on parameters C4, C5 and C6
•
If parameter C11 is set to 1, the pin probe will function as
the cabinet probe and the storage operation will continue
The same
Consequences if the error occurs while in "stand-by" mode:
as for the
•
Only timed operation cycles will be allowed to start
previous case,
Consequences if the error occurs during a timed chilling
but in relation
operation:
to the pin
•
Chilling will continue
probe
Consequences if the error occurs during a set-temperature
chilling operation:
•
Chilling will continue in timed mode
Consequences if the error occurs during storage mode:
•
Storage will continue