Cleaning, Care & Maintenance; Cleaning The Condenser - Polar CK640 Manual De Instrucciones

Ocultar thumbs Ver también para CK640:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 74
UK
To select a
parameter
To modify a
parameter:
To exit the
procedure
Note: Interrupt the power supply after altering the parameters.
Cleaning, Care & Maintenance
Switch off and disconnect from the power supply before cleaning.
Clean the interior of the appliance as often as possible.
Do not use abrasive cleaning agents. These can leave harmful residues.
Clean the door seal with water only.
Always wipe dry after cleaning.
Do not allow water used in cleaning to run through the drain hole into the evaporation pan.
Take care when cleaning the rear of the appliance. Sharp edges can cut.
A POLAR agent or qualified technician must carry out repairs if required.

Cleaning the condenser

Periodically cleaning the condenser can extend the life of the appliance.
POLAR recommend that a POLAR agent or qualified technician clean the condenser.
Cleaning the water pan
The water pan is located underneath the evaporator at the back of the unit.
To remove it for cleaning, simply slide out when necessary.
Alarms
Code
Message
AL
Minimum temperature
alarm
AH
Maximum temperature
alarm
id
Micro-port input alarm
(only in "stand-by" mode
and if parameter i0 is set
to 0 or 1)
iA
Compressor protection
input alarm (only if
parameter i0 is set to 2)
Note: When the cause that triggered the alarm has been resolved, the device restores
normal operation.
14
CK640_ML_A5_v4_20200728.indb 14
CK640_ML_A5_v4_20200728.indb 14
press
or
press
press
or
within 15 s
press
or leave for 15 s
press
and
for 4 s , or leave for 60 s
Remedies
Check the cabinet temperature
Check parameters A1 and A2
Check the cabinet temperature
Check parameters A3 and A4
Check the causes which activated
the input
Check parameters i0 and i1
Check the causes which activated
the input
Check parameters i0 and i1
Consequences
The device will continue
to function normally
The device will continue
to function normally
The outcome set by
parameter i0
The compressor will be
shut down
2020/7/28 17:38
2020/7/28 17:38
Tabla de contenido
loading

Tabla de contenido