3.1.4. LIMITER
In this tab you can enable and adjust the different sections of the limiter by clicking on its respective
the window.
In the graph you can see the curve obtained after the application of each element (highlighted line). The dashed line
will show the bypass condition (in order to compare both cruves).
.
Take into account that outputs 1 to 7 has the same Limiter and the Output 8 has its own Limiter
configuration.
Limiter
It set with the top point of the graph with the Threshold knob. When enable, it pass to gray color and can be moved
and set its level.
Compressor
Compression is set to the next point, also changing to gray to allow movement. with the Compression knob you can
adjust the ratio.
Noise Gate
A noise gate is set to the lowest point, the ratio can be adjusted with the related knob.
Like each DSP section, a command sentence will appears in OSC HISTORY each time that we change any value.
IMPORTANT
NOTE: Each Limiter
section can be enabled
or not. Simply push
the chosen selection.
Use the Copy/Paste
icon to copy the
Limiter setting. In that
case from Limiter 1-7
to Limiter 8 or viceversa.
MX
MKII
tab inside
NOTE: The highlighted
line represent the response
curve after apply the
Limiter elements. The
other curve show the
response in Bypass state.
PAGE 16