Work Pro Digiline Serie Manual De Usuario página 16

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

In this example, we have configured a 5th order Butterworth High Pass filter at 70 Hz and a 4th order Linkwith-Riley
Low Pass filter at 16 kHz.
The curve response is showed in the graphic window.
Using the Copy/Paste icon, it is possible to copy this filter to another output
Like each DSP section, a command sentence will appear in OSC HISTORY each time that we change any value.
In that case, the last action has been to create the Low Pass filter to Output 1 with the example values.
At this moment, the Complete Response and if it is shown only Output 1, you can see the complete response
after applying the Xover and EQ filter explained in this example.
MX
MKII
PAGE 15
Tabla de contenido
loading

Productos relacionados para Work Pro Digiline Serie

Este manual también es adecuado para:

Digiline mx mkii

Tabla de contenido