H 55
Place the gas bottle on the base and fit the regulator to the bottle. On opening the regulator,
check that there are no gas leaks by applying scapy water with a paintbrush at the union of the
flexible tube with the heater and with the regulator.
Fit the back panel using the attached fixing lugs.
Note: Changing of the bottle should be carried out in a non‐flammable environment.
The heater incorporates a safety device which extinguishes the pilot flame if the ventilation in
the premises is insufficient. It is usual for this device to operate in very small premises and
if the heater does go out, ventilate the room well and wait a few minutes before reigniting the
heater.
IGNITION INSTRUCTIONS
Attention: before using the apparatus for the first time and after long periods of non‐use, we
recommend switching on the control buttons several times alternately and without gas flow in
.
order to facilitate working
The heater can be regulated to three different heat intensities: MAXIMUM, MEDIUM and
MINIMUM. The switch‐on mechanism is piezo‐operated. Open the gas outlet by changing the
position of the upper lever on the regulator.
Turning on the catalytic
Press the button and roll it to your left, hold it down for 20 seconds.
Repeat this operation several times if necessary until the pilot light ignites at the bottom part
of the burner (where the spark is seen), Fig. 2 and hold the button for 10 seconds.
If, on releasing the button the flame goes out, please repeat the complete operation.
MINIMUM heat – Switch the button till
MEDIUM heat – Gire el botón hasta
MAXIMUM heat – Gire el botón hasta
To switch the heater off, close the gas tap.
MAINTENANCE
If any anomaly is observed or spare parts are required, contact our Technical Service.
The periodical maintenance must be carried out by exclusively by an authorized technician.
We would recommend that you have a service carried out every two years by an authorized
technician.
Watch the pilot light, which should be stable.
Check to see if it is necessary to change the flexible gas tube. If it proves necessary, obtain a
new tube and connect it as explained in Apparatus start‐up.
It is recommended that the cleaning of the apparatus be carried out with the gas tap closed,
the heater completely cold and with nonabrasive products.
9