Miele MF 02 RU Instrucciones De Montaje página 33

Módulo 2 de dosificación líquida del lado descontaminado-contaminado 7-12
Produktgruppe 512
33 von 36
am
Parts required
Quantity
Mat. no.
1
07285400
Note
Service and repair work should only be carried out by a suitably qualified electrician (with specialist training, knowledge
and experience, and recent related work experience) in accordance with all appropriate local and national safety
regulations.
Servicing, modification, testing and maintenance of electrical appliances should only be carried out in accordance with all
appropriate legal requirements, accident prevention regulations and valid standards.
All regulations of the appropriate utility supply companies and standards relating to safety (not limited to electrical safety)
are to be complied with.
Danger!
Even with the machine switched off, supply voltage may be applied to some components.
Before starting any service work, the machine must be disconnected from the power supply. Suitable measurements must
be made to ensure that this is the case.
A general visual check should always be carried out.
Incorrect conversion or service work could lead to a risk of fire.
Danger!
Grounding can be made ineffective if parts are reassembled incorrectly.
When reassembling the casing parts, it must be ensured that the grounding function operates correctly.
Carry out appropriate electrical safety checks.
Note
This kit, mat. no. 07285400 for PW 6163, PW 6243 and PW 6323, contains:
1 electronic EZL 230-A, module 2 (liquid dispensing 7-12)
1 electronics mounting bracket
1 keyed plug MFM 2-5 (EZL 230-A
1 adapter EV 230
8 spacers
1 wiring harness 48X-41X (EZL 230-A
1 wiring harness 49X-46X (EZL 230-A
1 wiring harness 47X-100X (EZL 230-A
1 wiring harness 51X-52X-101X (EZL 230-A
1 green/yellow ground wire 0.75x400
3 M4 nuts
3 M4x12.5 hex screws
1 accessory module for liquid dispensing (7-12)
1 wiring diagram, multifunction module 2 dispensing 2 (pumps 7-12), mat. no. 07033903
These instructions, Module 2 liquid dispensing 7-12 clean-soiled side , mat. no. 07523811.
09.06.2010
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
Designation
MF02-RU Multifunction Module Clean-Soiled Side installation kit
42X), pins 2-5
48X / EZL 230-A
41X), plug housing 3-pin, 110 mm
49X / EZL 230-A
46X), plug housing 7-pin, 110 mm
47X / EV 230
110X), plug housing 7-pin, 1820 mm
51X-52X / EV 230
Umbau- und Montageanweisung
111X), plug housing 8-3-pin, 2600 mm
M.-Nr. 07523811