Before Calling for Service

Before calling customer service, consider the
suggestions and instructions below:
Fault
The ... symbol will
appear after a few sec-
onds.
The ... symbol will
appear after the pump
has been running for
2 minutes.
The vacuum-sealing
process will not start.
The ² symbol does not
appear even though the
lid is closed.
If you try to operate the
appliance several times
in succession, the vac-
uum-sealing process
seems to run as normal
but the bag is not heat-
sealed.
The vacuum-sealing
process is taking lon-
ger and longer.
18
Error
The vacuum cannot be
created properly.
It is taking too long to
create a vacuum. Your
selected vacuum-seal-
ing level cannot be
reached.
The appliance is not
detecting the lid.
9
CAUTION
Repairs should only be done by an authorized
servicer.
Improper repair of your appliance may result in risk
of severe physical injury or death.
Causes
The glass lid has not been
closed properly.
The seal on the glass lid is not
fitted properly or is malfunction-
ing.
The seal on the glass lid has mis-
shaped.
The lid on the external vacuum-
sealing container has not been
closed properly.
The external vacuum-sealing con-
nection is not positioned cor-
rectly on the vacuum-sealing
chamber's air outlet.
As the temperature rises, liquids
begin to heat. At this point, the
process of creating a vacuum
stops.
The door switch on the glass lid
is not working or is not being
detected by the appliance.
The thermal switch on the heat-
sealing transformer has been
triggered.
There is too much moisture in the
pump system.
The pump system is extremely
hot.
Possible remedy
Open and close the glass lid
again. When doing so, lightly
press on the glass lid for the first
few seconds.
Check the seal.
Gently press the seal to
straighten it out.
Check the position of the vacuum-
sealing lid. Only use suitable vac-
uum-sealing containers.
Check the position of the external
vacuum-sealing connection.
Only vacuum-seal cold liquids.
If the vacuum-sealing chamber is
wet, wipe it dry.
Heat-seal the vacuum-sealing bag
early if large bubbles form.
Select a lower vacuum-sealing
level.
Call Customer service.
Allow the appliance to cool for at
least 10 minutes. Then try again.
Allow the appliance to cool for at
least 2 minutes between vacuum-
sealing operations.
The appliance monitors the vac-
uum-sealing as it progresses. If
too much liquid is retained in the
pump oil, the ¢ symbol will
appear. Initiate drying.
Allow the appliance to cool and
then try again.